Stake excavation depth
and verticality Measurement
Smart System
Features
  • NRTL-UL61010-1, CASC22.2 Certification
  • E-LVD(2014/35/EC), EMC(2014/30/EU), RoHS(2011/65/EU) Certification
  • Korea Institute of Water Technology Certification: KC Sanitary Safety Standards Certification
  • Waterproof dustproof grade IP67
  • Two-way flow measurement is possible
  • Driving part, No obstruction or wear required maintenance
  • Excellent chemical durability and use PFA or PDFF liner material
  • Various electrodes available for sensors
  • Maintain stable accuracy even in noisy and vibrating sites
Automatic measurement and storage of cement paste placement plant flow rates
KTM-800 flow meter
Structural map
Section Specification
Size 10A (3/8") - 2000A (80")
Process Connection lange type - Standard JIS10K RF
(Option. ANSI 150#, DIN 16 bar)
Measuring Range 0.028 m3/h – 113040.0 m3/
Flow Velocity 0.1 m/s – 10 m/s
Accuracy ±0.5 % R.D (1 m/s ~ 10 m/s)
±0.5 % F.S (0.1 m/s ~ 1 m/s)
Fluid Temperature TFE (-10 ℃ ~ 160 ℃)
Hard rubber (-10 ℃ ~ 70 ℃)
Ceramic (-10 ℃ ~ 150 ℃) - Option
Ambient Temperature -10 ℃ ~ 60 ℃
Conductivity 5 ㎲ / cm or more
Power Supply C 85-250 V (50~60) Hz
DC 24 V – (Option)
Battery 4EA - 3.6 V (Option),
Battery Life 1 year
Power Consumption 15 VA
Display LCD Display
Flowrate : 5-digit Display
Total : 9-digit Display / With Back light
Output nalog : DC 4-20 mA
Pulse : DC (8~30) V (Open collector pulse)
Digital : RS-485
Mixing of fixed liquid in real time, measurement and visualization of pressure transfer flow rate
01
Date and time of work/site tool/worker/setup/communication/program termination
02
Display Graphs
Current Excavation Depth
auger current
Current cement injection flow rate
Total cumulative cement injection
03
Excavation information
Current depth
Ground Level
excavation speed
maximum depth
Working hours
04
Cement injection
Infusion flow rate
Total cement injection
05
Pile Information
Name of the stake
final penetration
06
Data Information for Plant Equipment
mixed stirrer
Flow meter value
Slope meter (x,y)
Auger motor current value
07
The operation part of the plant equipment
Operation start/pause/restore/stop paste injection start/stop injection final penetration measurement/ paste flow record depth zero/use auxiliary anti-pile/timer
Construction data real-time server transfer and remote monitoring
Construction Recorder Data
Installation and commissioning
Iksan Peace Zone 1 in Jeollabuk-do
Excavation process
In-depth meter
Installation of a slope meter
AUGER MOTOR CURRENT MEASUREMENT
Flowmeter & RF communication module
Real-time Plant Paste Flow Measurement Unit
Driver room monitoring & operation department